Change Currency: GBP USD EUR

Change Language: 
      Deutsch
    
      Dansk
    
      English (UK)
    English (US) 
      Español
    
      Française
    עברית (ישראל) 
      Dutch
    
      Türkçe

PCsensor- Usb temperature sensor,outer waterproof probe, support email alarm (TEMPer1)

$35.00 $16.50

1.0 average, based on 1 reviews

Manufacturer: PCsensor

Stock Level: 6

Product Information

1. Description

      Hid TEMPer1  is a measurement device using USB port to connect to a computer or other machines. It can measure the temperature of the machine and the environment accurately. It must be connect to the computer to start working. Hid TEMPer1 can be use in computer room, weather, environment and special environment temperature testing.

2. Function & Feature

Range of measuring: TEMPer -40~+120 C; -40~+248F;

Resolution rate: 0.0625C

Typical accuracy:     ±2°C (over the full temperature range of –40°C to 125°C )
                              ±1°C (over the range of 0°C to 100°C)

Electricity:< 10 mA;

Voltage : 5V

Support Windows NT,XP, Vista;

Memory requirement: 20M

Data auto save to be txt or csv format, can be open by Excel;

Send mails function

Graph transfer function

Probe cable length about 1m

 
DETAIL:
CapsLock and NumLock:
You don’t want to install software, OK! You can use the CapsLock and NumLock function.
As long as you long press the CapsLock or NumLock for 3 seconds, you can read the temperature no matter in excel, text or word form without running software. Then you can create curve.
   Caps Lock   NUM lOCK
 
        DATA

3. INSTALLING INSTRUCTION
 
Software installing instruction: please go to our website to download the process
a) Install dotnetfx.exe, if your computer system is Vista, may be you don’t need to install this process. Dotnetfx.exe is framework 2.0 of Microsoft; you can download it from the website of Microsoft;
b) Decompress TEMPer V22.2.rar to you computer, and running TEMPer V22.2.exe.
Hardware installing:
Plug the thermometer into the USB port of the computer to connect it. If you plug it correctly the red light in the device will be turned on. 

4.Operating instruction    (Note: Our software just support windows OS.)

 
1)       THE TEMPERATURE DISPLAY BOX and MESSAGE FRAME
 
The Real Time Temperature will Display in the Temperature Box on the Top Left Corner of software interface (see picture1 ). And the Action of Operation will Display on the Top Right Corner  (see picture2).

  READ           READ             
Picture1                          picture2
 
2)       CURVES DISPLAY
 
There is Two Curves, One is AVG Line and the Other is Current Line. The User can Check the Situation of Temperature Contrastively. The Curves can Real-time Display the Changing Situation of Temperature. The Tendency of Curves Responds the Real-time Temperature Situation. (see picture3)
ADVISE: Please Check the Log or Data File in Save Contents When You Want to Check the Historical Data.

curve

                             Picture3
3)       LOG
Record the Real-time Temperature Data and Save Them in the Related File Automatically, Such as 2011-3-22 17h48m54s.csv,2011-3-22 17h48m54s.txt. (see picture4)
 
log 
Picture4
 
4)       MSN FUNCTION
After the MSN User Log in, His Friends can Operate by Related Tips and Obtain the Temperature Data. Your Friends can obtain the Temperature Data Automatically When He Send “1”in According with Tips. The Temperature Data Including: Real-time Temperature, Maximum Value, Minimum Value and Average Value. (see picture 5)
 MSN
 
Picture5 
 
MSN
Picture 6 (read temperature)
 
5)       EMAIL FUNCTION
 
Fill in the Related Information of Email and Save it. The Requirement of Send Email: Support POP3/SMTP and Other Server Port. Receive Email you can fill in two.
Related Function: 1) when the Alarm is on, it will send the Email to Specified Email Box Automatically if the Temperature Reach the Alarm Limit. 2) You can set the Sending Interval, and then it will send the Email to the Specified Mail Box at Set Intervals. (Advise) 3) it can Send Email Continuously to the Specified Mail Box. (Deprecated feature) (See picture 9)
Email 
 
Picture 7 
  
6)       THE SAVING SETTING OF FILE
Select “Tool->Option->Memory Setting” then you can Set the Saving File Catalog, File Type and the Maximum Record Count the File can Save. (see picture8)
storage
 
 
Picture 8
 
7)        THE ALARM SETTING
Set the Temperature of Alarm and Open it. When the Temperature Reach the Higher Limit, the Voice of Alarm will Play, and it will Stop when the Temperature Drop to the Lower Limit.
Select “Toll->Select->Alarm”  (see picture 9)
Alarm 
 
See picture 9
 
8)       TEMPERATURE CORRECTION and UNIT SELECTION
When a Small Deviation occurs between the Displaying Temperature and the Actual Temperature, you can correct it through this Function. And you can select the unit of the temperature. (See picture 10)
 
setting
see picture 10
 
9)       CHANGE THE COLOR OF BACKGROUD
Select “Tool->Select->Color Setting”, Click Color Frame or Button to Choose the Color you Like (see picture 11)
 
color setting
See picture 11
 
10)       CHANGE LANGUAGE
Select “Tool->Select->Language, then Choose English or Chinese” (see picture 12)
 
language
see picture 12
 
NOTE
1. We suggest you to Reboot Software after Changing “Memory Setting” or “Unit Setting”. It will make sure your Setting cans Take Effect.
2.  If the Curves Fluctuate greatly, it maybe you do not Reboot Software in Time after Setting Unit.
 
5. Packing specification  
  

Name of the part

Specification

Quantity

TEMPer 1

 

1

Driver CD

3.5inch

1

Using instruction card

-

1

 

 

  

 

 

 

 

(Weight of TEMPer1 :44g) 

 

 

FRONT

 Picture 1 Finished product (Front)

BACK

  Picture 2 Finished product ( back)

6. Certificate

Note: If you want to download the latest software, please click herehttp://pcsensor.com/index.php?_a=document&doc_id=6

 

Product Code: TEMPer1

Customer Reviews

Average Rating: 1

appriciation

this device tell me good heath of my aound

shabbir :: Apr 05 2011, 11:37 AM

Write a review

 

© 1999-2012 PCsensor  

Mobile Site